LSB Version: :base-4.0-amd64:base-4.0-noarch:core-4.0-amd64:core-4.0-noarchĭescription: Red Hat Enterprise Linux Server release 6.6 (Santiago)įilename: /lib/modules/2.6.32-573.7.1.el6.x86_64/weak-updates/hpsa/hpsa.koĭescription: Driver for HP Smart Array Controller version 3.4. System Programmable Logic Device Version 0x34 System Board.Smart Array P440ar Controller 6.60 Embedded.System Board Server Platform Services (SPS) Firmware 3.1.3.21.0 System Board.SAS Programmable Logic Device Version 0x03.Redundant System ROM P89 v2.52 () System Board.I have tried to inspect this key in hpsmart array cli, apparently, 60days in demo.
Intelligent Platform Abstraction Data 25.13 System Board Hp smart array p222/512mb fbwc 6gb 1-port int/1-port ext sas controller 631667-b21 the hp smart array p222 controller is a low profile, 6 gb/s, pcie 3.0, serial attached scsi sas raid controller that provides entry-level, storage performance, scalability, and data protection for select hp proliant gen8 rack and tower servers.About HPE Accessibility Careers Contact Us Corporate Responsibility Global Diversity & Inclusion HPE Modern Slavery Transparency Statement. HPE Smart Storage Battery 1 Firmware 2.1 Embedded Why HPE Products Support Contact Shopping Cart United States (EN) Configuring Arrays on HP Smart Array Controllers Reference Guide.
Its always recommended to keep the hardware Firmware and Drivers Updated to the latest supported version for OS. However it should be reported on you hardware logs for any errors and warnings.
(Previous lock up code = 0x12) Action: Install the latest controller firmware.
HPE Blog, Austria, Germany & Switzerlandįor two months I have this error on my servers, D元80 G9. Modular Smart Array 1000 Controller User Guide 11 Overview 1 The MSA1000 Controller is a drive array controller specifically designed for installation in the MSA1000 and the MSA1500 cs storage products.How do I actually monitor drive health? is there a way to get some kind of alert if a drive fails telling me which drive has actually failed? Otherwise I can imagine the server could be up for long time and the only time I will know it fails is if two drives fail and the raid logical drive is no longer accessible. Can I safely just remove the failed hot-swap drive and plug in new one? will the controller automatically re-build without me having to go into the controller utility and initiate some kind of re-build?Īlso, if only one drive is allowed to fail. Tips: check for the LED lights in the back of the controller, if the Smart Array works they are all lighted up and green. I found another one in my company storage, changed it and magically the Bios recognised the new controller and all the drives. So lets say I am running Ubuntu Server on there, and one drive was to fail. The problem was the Smart Array P400 was broken. Can I create a RAID5 array with these 3 drives? what will be my logical drive size?Īlso, from the research I have done on RAID5, one drive can fail without effecting the operating system or having any data-loss. I have 2x 500GB SATA drives and 1x 1TB sata drive.
I have a old HP proliant server with the HP Smart Array P410i controller.